一、发射功率的测量步骤

工具:频谱仪

版本:功率版本

使用步骤:

1. 查询模块型号,工作电压,默认参数(如信道,波特率等),工作模式连接方式,打开串口软件,确认串口未发送数据(若未加衰减器,会损坏仪器)

*下面以E32-433T30D为例

E32-433T30D参数配置工具:
forward?url=https%3A%2F%2Fmmbiz.qpic.cn%2Fmmbiz_png%2FEvvXlctHqfeGXOD3pwbY9G2icoY9FLNWQoBMFc9Xp6MUMLhb4HIhytANBdZczjicdr38qnBPKOeut17YPiavNzcng%2F640%3Fwx_fmt%3Dpng&s=bc5edc
E32-433T30D工作电压:
forward?url=https%3A%2F%2Fmmbiz.qpic.cn%2Fmmbiz_png%2FEvvXlctHqfeGXOD3pwbY9G2icoY9FLNWQ6sr3VMHnpkbgbgLDFicFN5LZhMgL1K571qj1icUwEj3qNibJo5Fye52pA%2F640%3Fwx_fmt%3Dpng&s=8b9da6
E32-433T30D工作模式连接方式:
forward?url=https%3A%2F%2Fmmbiz.qpic.cn%2Fmmbiz_png%2FEvvXlctHqfeGXOD3pwbY9G2icoY9FLNWQxwutSlLbka7ppSNqtQUzib8BnTmTFJ37DeUZ4PQmD0pG2t5fSczvlYg%2F640%3Fwx_fmt%3Dpng&s=422c67

串口软件Xcom:

forward?url=https%3A%2F%2Fmmbiz.qpic.cn%2Fmmbiz_png%2FEvvXlctHqfeGXOD3pwbY9G2icoY9FLNWQJj6ib44aHjqAII0DDpFElvKQuh64bCt1Y624CF8qtWb3DOa35h97WmA%2F640%3Fwx_fmt%3Dpng&s=b727a6
频谱仪按键:
forward?url=https%3A%2F%2Fmmbiz.qpic.cn%2Fmmbiz_png%2FEvvXlctHqfeGXOD3pwbY9G2icoY9FLNWQexuJ9BcTEU35LeRnC53n0L0lV0dVDDMdaWa1qPySQ9kLgqMoPnsadg%2F640%3Fwx_fmt%3Dpng&s=6837c9


2. 设置频率Freq:按按键“Freq”设置仪器中心频率(与模块发射频率一致)。

3. 设置功率补偿:按键“AMPTD”选择第二页第二个Ref lv:offest,设置对应频段功率补偿(根据该仪器连接衰减器查询补偿功率)。

4. 设置扫描宽度:按仪器“SCAN”按键,根据模块发射频率以及需要测量的值选择测试宽度。(一般我们选择100MHz)

5. 设置BW:按仪器“BW”按键,BW的值对应了扫描的快慢,根据要测量的值选择对应的BW。(一般我们选择100KHz)

6. 完成1-5步骤之后,更改模块工作模式,如透传,通过串口工具命令模块发送数据,按“Peak Search”按键,接着按仪器“TRACE”按键,选择Max hold选对应模块发射频率的点就是模块发射功率。

forward?url=https%3A%2F%2Fmmbiz.qpic.cn%2Fmmbiz_png%2FEvvXlctHqfeGXOD3pwbY9G2icoY9FLNWQHicQIyL4KheK4WKEYg0NQBUmDhCN91wzSKbHm4y2QE0Rb4iaVXbe9cJw%2F640%3Fwx_fmt%3Dpng&s=7674f0

二、二次谐波的测量步骤

工具:频谱仪

版本:功率版本

完成1-6步骤之后,按“PEAK”按键,选择或输入频率为两倍频率的点,(如E32-433T30D默认频率433MHz,二倍频率就为866MHz,此时需要重新设置SCAN,使其包括866Mhz),该点就为二次谐波点。

forward?url=https%3A%2F%2Fmmbiz.qpic.cn%2Fmmbiz_png%2FEvvXlctHqfeGXOD3pwbY9G2icoY9FLNWQBIUeEZLwUJgOWnkvvFicVLSicXciaRG9QEDDFw49lDic5z7pBGM4Yhia0KA%2F640%3Fwx_fmt%3Dpng&s=db6310

三、邻信道功率比的测量步骤

工具:频谱仪

版本:功率版本

在前面1-6步骤基础上按“meas”按键,选择ACP,Center Freq选择发射频率,如E32-433T30D默认信道23,因此选择频率433Mhz,再按“meas setup”按键,选择offset/LImits将offset Freq与lntey bw设置为该模块一个信道所占用的带宽频率。

forward?url=https%3A%2F%2Fmmbiz.qpic.cn%2Fmmbiz_png%2FEvvXlctHqfeGXOD3pwbY9G2icoY9FLNWQgerwc4aVXP50xOhLZtsRVJNeWV6P3vR4JOwpvuUup44ayoA1JaKwvQ%2F640%3Fwx_fmt%3Dpng&s=22a206

再按“meas setup”按键,选择carrier setup后选择configure carriers将carrier Spacing与Measurement设置为该模块一个信道所占用的带宽频率,此时,按“Trace”按键,选择Max Hold,此时就为邻信道功率比。(邻信道功率比dBc)

forward?url=https%3A%2F%2Fmmbiz.qpic.cn%2Fmmbiz_png%2FEvvXlctHqfeGXOD3pwbY9G2icoY9FLNWQhCia1Rve42vXoK14jia4ts6Ce5CDL6gFhbYVYAmHQYct7CTkPic1IHYsQ%2F640%3Fwx_fmt%3Dpng&s=869ceb

四、频率准确度的测量步骤

工具:频谱仪

版本:功率版本

选择按键“Freq”将中心频率设置为晶振频率,然后调整span与BW(晶振至少保留的小数位数),按“Peak Search”按键选择NEXT PEAK,然后按“Trace”选择Max Hold选择最大值,如无明显变化,后又再次调整span与BW直到屏幕中有明显的凸起点。(该截图为E32-433T30D测试结果  其中span为 200Hz,bw为100kHz)